Technical information for healthcare professionals. For the patient leaflet, see Levosert 20 microgram/24 hours Intrauterine Delivery System patient leaflet.
Contraception.
Treatment of heavy menstrual bleeding. Levosert may be particularly useful in women with heavy menstrual bleeding requiring (reversible) contraception.
Posology
Levosert is inserted into the uterine cavity and is effective for eight years in the indication contraception and has a demonstrated efficacy for 3 years for the indication heavy menstrual bleeding. Therefore, Levosert should be removed or exchanged after 8 years of use, or earlier if heavy or bothersome menstrual bleeding returns.
Insertion
It is strongly recommended that Levosert should only be inserted by healthcare professionals who are experienced in IUS insertions and/or have undergone training for the Levosert insertion procedure.
Before insertion, the patient should be carefully examined in order to detect any contraindication to IUS insertion. Exclude pregnancy before insertion. Consider the possibility of ovulation and conception before using this product. Levosert is not suitable for use as a post-coital contraceptive (see section 4.3 and section 4.4 under Medical examination).
Contraception and heavy menstrual bleeding
Table 1. When to insert Levosert in women of fertile age
Starting Levosert
- Levosert should be inserted into the uterine cavity within 7 days of the onset of menstruation. In this case Levosert provides contraceptive protection upon insertion and no back-up contraception is needed.
- If insertion within 7 days of the onset of menstruation is not possible or the woman does not experience regular menses, Levosert may be inserted at any time during the menstrual cycle provided that the healthcare professional can reliably exclude the possibility of prior conception. However, in this case immediate contraceptive protection upon insertion is not reliably ensured. Therefore, a barrier method of contraception should be used or the patient should abstain from vaginal intercourse for the next 7 days to prevent pregnancy.
Postpartum insertion
In addition to the instructions above (Starting Levosert):
Postpartum insertions should be postponed until the uterus is fully involuted, however should not be performed earlier than 6 weeks after delivery. If involution is substantially delayed, consider waiting until 12 weeks postpartum.
Insertion after first-trimester abortion
Levosert can be inserted immediately after first trimester abortion. In this case no back-up contraception is needed.
Replacing Levosert
Levosert can be replaced by a new system at any time in the menstrual cycle. In this case no back-up contraception is needed.
Changing from another contraceptive method (e.g., combined hormonal contraceptives, implant)
- Levosert can be inserted immediately if it is reasonably certain that the woman is not pregnant.
- Need for back-up contraception: If it has been more than 7 days since menstrual bleeding began, the woman should abstain from vaginal intercourse or use additional contraceptive protection for the next 7 days.
Important information to consider during or after insertion
In case of difficult insertion and/or exceptional pain or bleeding during or after insertion, the possibility of perforation should be considered and appropriate steps should be taken, such as physical examination and ultrasound.
After insertion, women should be re-examined after 4 to 6 weeks to check the threads and ensure that the device is in the correct position. Physical examination alone (including checking of threads) may not be sufficient to exclude partial perforation, and ultrasound may be considered (see section 4.4).
Removal/replacement
Levosert is removed by gently pulling on the threads with forceps. If the threads are not visible and the system is found in the uterine cavity on ultrasound exam, it may be removed using a narrow forceps. This may require dilatation of the cervical canal or surgical intervention. After removal of Levosert, the system should be examined to ensure it is intact.
During difficult removals, single cases have been reported of the hormone cylinder sliding over the lateral arms and hiding them together inside the cylinder. This situation does not require further intervention once completeness of the IUS has been ascertained. The knobs of the lateral arms usually prevent complete detachment of the cylinder from the T-body.
Continuation of contraception after removal
• If the woman wishes to continue using the same method, a new system can be inserted immediately following removal of the original system.
• If the woman does not wish to continue using the same method but pregnancy is not desired, the removal should be carried out within 7 days of the onset of menstruation, provided the woman is experiencing regular menses. If the system is removed at some other time during the cycle or the woman does not experience regular menses and the woman has had intercourse within a week, she is at a risk of pregnancy. To ensure continuous contraception a barrier contraceptive method should be used (such as condoms) starting at least 7 days before the removal. After removal, the new contraceptive method should be started immediately (follow the instructions for use of the new contraceptive method).
Special populations
Paediatric population
Levosert has not been studied in patients below 16 years of age. Levosert should not be used before menarche.
Elderly
There is no indication for the use of Levosert in postmenopausal women.
Hepatic impairment
Levosert is contraindicated in patients with liver tumour or other acute or severe liver disease (see section 4.3).
Renal impairment
Levosert has not been studied in women with renal impairment.
Method of administration
To be inserted by a healthcare professional using aseptic technique.
Levosert is supplied in a sterile pack which should not be opened until required for insertion. Do not resterilise. For single use only. The exposed product should be handled with aseptic precautions. If the seal of the sterile package is broken, the product should be discarded (see section 6.6 for disposal instructions). Do not use if the inner package is damaged or open. Do not insert after the expiry date which is stated on the carton and the pouch after EXP. The expiry date refers to the last day of that month.
Levosert is supplied with a patient reminder card in the outer carton. Complete the patient reminder card and give it to the patient, after insertion.
Preparation for insertion
• Examine the patient to rule out contraindications for the insertion of Levosert (see section 4.3 and section 4.4 under Medical examination).
• Insert a speculum, visualize the cervix, and then thoroughly cleanse the cervix and vagina with a suitable antiseptic solution.
• Employ an assistant as necessary.
• Grasp the anterior lip of the cervix with a tenaculum or other forceps to stabilize the uterus. If the uterus is retroverted, it may be more appropriate to grasp the posterior lip of the cervix. Gentle traction on the forceps can be applied to straighten the cervical canal. The forceps should remain in position and gentle counter traction on the cervix should be maintained throughout the insertion procedure.
• Advance a uterine sound through the cervical canal to the fundus to measure the depth. If uterine depth is < 5.5 cm discontinue the procedure. Confirm the direction of the uterine cavity and to exclude any evidence of intrauterine abnormalities (e.g., septum, submucous fibroids) or a previously inserted intrauterine contraceptive which has not been removed. If difficulty is encountered, consider dilatation of the canal. If cervical dilatation is required, consider using analgesics and/or a paracervical block.
Levosert is inserted with the provided inserter into the uterine cavity by carefully following the insertion instructions provided in the box containing the Levosert IUS.
- Known or suspected pregnancy,
- Current or recurrent pelvic inflammatory disease;
- Lower genital tract infection;
- Postpartum endometritis;
- Infected abortion during the past three months;
- Cervicitis, cervical dysplasia;
- Suspected or confirmed uterine or cervical malignancy;
- Liver tumour or other acute or severe liver disease;
- Congenital or acquired abnormality of the uterus including fibroids if they distort the uterine cavity;
- Undiagnosed abnormal uterine bleeding;
- Conditions associated with increased susceptibility to infections;
- Current or suspected hormone dependent tumours such as breast cancer (see section 4.4);
- Acute malignancies affecting the blood or leukaemias except when in remission,
- Recent trophoblastic disease while hCG levels remain elevated;
- Hypersensitivity to the active substance or to any of the excipients listed in section 6.1.
Medical examination
Before insertion, a complete personal and family medical history should be taken. Physical examination should be guided by this and by the contraindications and warnings for use. Pulse and blood pressure should be measured and a bimanual pelvic examination performed to establish the orientation of the uterus. Prior to insertion pregnancy should be excluded and genital infection should be successfully treated. Women should be advised that Levosert does not protect against HIV (AIDS) and other sexually transmitted disease (please refer to the section below on pelvic infections).
The patient should be re-examined 4 to 6 weeks after insertion to check the threads and ensure that the device is in the correct position. Vaginal ultrasound examination may be considered to ascertain the correct position of the system. In case Levosert cannot be located in the uterine cavity, expulsion or complete perforation should be considered (see paragraph “perforation” below) and X-ray may be used. Thereafter, re-examination should be performed once a year or more frequently if clinically indicated.
Women should be encouraged to attend cervical and breast screening as appropriate for their age.
Levosert is not for use as a post-coital contraceptive.
Conditions under which Levosert can be used with caution
Levosert may be used with caution after specialist consultation, or removal of the system should be considered, if any of the following conditions exist or arise for the first time during treatment:
- Migraine, focal migraine with asymmetrical visual loss or other symptoms indicating transient cerebral ischemia
- Unusually severe or unusually frequent headache
- Jaundice
- Marked increase of blood pressure
- Malignancies affecting the blood or leukaemias in remission
- Use of chronic corticosteroid therapy
- Past history of symptomatic functional ovarian cysts
- Active or previous severe arterial disease, such as stroke or myocardial infarction
- Severe or multiple risk factors for arterial disease
- Thrombotic arterial or any current embolic disease
- Acute venous thromboembolism.
Levosert may be used with caution in women who have congenital heart disease or valvular heart disease at risk of infective endocarditis.
Irregular bleedings may mask some symptoms and signs of endometrial polyps or cancer, and in these cases diagnostic measures have to be considered.
In general, women using Levosert should be encouraged to stop smoking.
Insertion / removal warnings and precautions
General information: Insertion and removal may be associated with some pain and bleeding. In case of difficult insertion and/or exceptional pain or bleeding during or after insertion, physical examination and ultrasound should be performed immediately to exclude perforation of the uterine corpus or cervix (see also 'Perforation').
The procedure may precipitate fainting as a vasovagal reaction or a seizure in an epileptic patient. In the event of early signs of a vasovagal attack, insertion may need to be abandoned or the system removed. The woman should be kept supine, the head lowered and the legs elevated to the vertical position if necessary in order to restore cerebral blood flow. A clear airway must be maintained; an airway should always be at hand. Persistent bradycardia may be controlled with intravenous atropine. If oxygen is available it may be administered.
Perforation: Perforation of the uterine corpus or cervix may occur, most commonly during insertion, although it may not be detected until sometime later. In some cases, the device may migrate to the intra-abdominal area. This may be associated with severe pain and continued bleeding. If perforation is suspected the system should be removed as soon as possible; surgery may be required.
The incidence of perforation during or following Levosert insertion in the clinical trial, which excluded breastfeeding women, was 0.1%.
In a large prospective comparative non-interventional cohort study in IUS/IUD users (N = 61,448 women), the incidence of perforation was 1.3 (95% CI: 1.1‑1.6) per 1,000 insertions in the entire study cohort; 1.4 (95% CI: 1.1‑1.8) per 1,000 insertions in the cohort for another LNG-IUS and 1.1 (95% CI: 0.7‑1.6) per 1,000 insertions in the copper IUD cohort.
The study showed that both breastfeeding at the time of insertion and insertion up to 36 weeks after giving birth were associated with an increased risk of perforation (see Table 2). These risk factors were independent of the type of IUS/IUD inserted.
Table 2: Incidence of perforation per 1,000 insertions for the entire study cohort, stratified by breastfeeding and time since delivery at insertion (parous women)
Breastfeeding at time of insertion
Not breastfeeding at time of insertion
Insertion ≤ 36 weeks after delivery
5.6
(95% CI 3.9-7.9; n=6,047 insertions)
1.7
(95% CI 0.8-3.1; n=5,927 insertions)
Insertion > 36 weeks after delivery
1.6
(95% CI 0.0-9.1; n=608 insertions)
0.7
(95% CI 0.5-1.1; n=41,910 insertions)
Breast‑feeding at the time of insertion and insertion up to 36 weeks after giving birth were confirmed as risk factors also in the subgroup that were followed up for 5 years.
The risk of perforation may be increased in post-partum insertions (see section 4.2), in lactating women and in women with a fixed retroverted uterus.
Re-examination after insertion should follow the guidance given above under the heading "Medical examination" including the consideration to use vaginal ultrasound examination to ascertain the correct position of the system 4 to 12 weeks thereafter, which may be adapted as clinically indicated in women with risk factors for perforation.
Pelvic infection: In users of copper intrauterine devices (IUDs), the highest rate of pelvic infections occurs during the first month after insertion and decreases later.
Known risk factors for pelvic inflammatory disease are multiple sexual partners, frequent intercourse and young age. Pelvic infection may have serious consequences as it may impair fertility and increase the risk of ectopic pregnancy. As with other gynaecological or surgical procedures, severe infection or sepsis (including group A streptococcal sepsis) can occur following IUS insertion, although this is extremely rare.
For women using Levosert with symptoms and signs suggestive of pelvic infection, bacteriological examinations are indicated and monitoring is recommended even with discrete symptoms, and appropriate antibiotics should be started. There is no need to remove Levosert unless the symptoms fail to resolve within the following 72 hours or unless the woman wishes Levosert to be removed. Levosert must be removed if the woman experiences recurrent endometritis or pelvic infection, or if an acute infection is severe.
Complications leading to failure
Expulsion: In clinical trials with Levosert in the indication contraception, the incidence of expulsion was low (<4% of insertions) and in the same range as reported for other IUDs and IUSs. Symptoms of partial or complete expulsion of Levosert may include bleeding or pain. However, a system can be expelled from the uterine cavity without the woman noticing it, leading to loss of contraceptive protection. As Levosert decreases menstrual flow, increase of menstrual flow may be indicative of an expulsion.
Risk of expulsion is increased in
• Women with history of heavy menstrual bleeding (including women who use Levosert for treatment of heavy menstrual bleeding)
• Women with greater than normal BMI at the time of insertion; this risk increases gradually with increasing BMI
Woman should be counselled on possible signs of expulsion and how to check the threads of Levosert and advised to contact a healthcare professional if the threads cannot be felt. A barrier contraceptive (such as a condom) should be used until the location of Levosert has been confirmed.
Partial expulsion may decrease the effectiveness of Levosert.
A partially expelled Levosert should be removed. A new system can be inserted at the time of removal, provided pregnancy has been excluded.
Lost threads: If the retrieval threads are not visible at the cervix on follow-up examination, first exclude pregnancy. The threads may have been drawn up into the uterus or cervical canal and may reappear during the next menstrual period. If they cannot be found, they may have broken off, the system may have been expelled, or rarely the device may be extra-uterine after having perforated the uterus. Vaginal ultrasound examination should be arranged to locate the device and alternative contraception should be advised in the meantime. If an ultrasound cannot locate the device and there is no evidence of expulsion, a plain abdominal X-ray should be performed to exclude an extra-uterine device.
Bleeding irregularities
Irregular bleeding: Levosert usually achieves a significant reduction in menstrual blood loss within 3 to 6 months of treatment. Increased menstrual flow or unexpected bleeding may be indicative of expulsion. If menorrhagia persists then the woman should be re-examined. An assessment of the uterine cavity should be performed using ultrasound scan. An endometrial biopsy should also be considered.
Risk in pre-menopausal women
Because irregular bleeding/spotting may occur during the first months of therapy in pre-menopausal women, it is recommended to exclude endometrial pathology before insertion of Levosert.
When to check for pregnancy in women of child bearing potential: The possibility of pregnancy should be considered if menstruation does not occur within six weeks of the onset of previous menstruation and expulsion should be excluded. A repeated pregnancy test is not necessary in amenorrhoeic subjects unless indicated by other symptoms. In women of fertile age, oligomenorrhoea and/or amenorrhoea develops gradually in about 20% of the users. For details of amenorrhoea rates, see section 5.1.
Treatment review advice for menorrhagia: Levosert usually achieves a significant reduction in menstrual blood loss within 3 to 6 months of treatment. If significant reduction in blood loss is not achieved in these time-frames, alternative treatments should be considered.
Other risks during use
Ectopic pregnancy: The absolute risk of ectopic pregnancy in users of levonorgestrel IUS is low. However, when a woman becomes pregnant with Levosert in situ, the relative likelihood of ectopic pregnancy is increased. The possibility of ectopic pregnancy should be considered in the case of lower abdominal pain - especially in connection with missed periods or if an amenorrhoeic woman starts bleeding.
In the conducted clinical study, the overall incidence of ectopic pregnancy with Levosert was approximately 0.12 per 100 woman-years. Women considering Levosert should be counselled on the signs, symptoms and risks of ectopic pregnancy. For women who become pregnant while using Levosert, the possibility of an ectopic pregnancy must be considered and evaluated.
Women with a previous history of ectopic pregnancy, tubal surgery or pelvic infection carry an increased risk of ectopic pregnancy. The risk of ectopic pregnancy in women who have a history of ectopic pregnancy and use Levosert is unknown. The possibility of ectopic pregnancy should be considered in the case of lower abdominal pain, especially in connection with missed periods or if an amenorrhoeic woman starts bleeding. Ectopic pregnancy may require surgery and may result in loss of fertility.
Ovarian cysts: Ovulatory cycles with follicular rupture usually occur in women of fertile age. Sometimes atresia of the follicle is delayed and folliculogenesis may continue. These enlarged follicles cannot be distinguished clinically from ovarian cysts. Most of these follicles are asymptomatic, although some may be accompanied by pelvic pain or dyspareunia.
In a clinical trial of Levosert that enrolled 280 women presenting with heavy menstrual bleeding of which 141 received Levosert, ovarian cyst (symptomatic and asymptomatic) was reported in 9.9% patients within 12 months of insertion. In a clinical trial of Levosert which enrolled 1,751 subjects, symptomatic ovarian cysts occurred in approximately 4.5% of subjects using Levosert, and 0.3 % of subjects discontinued use of Levosert because of an ovarian cyst.
In most cases, the ovarian cysts disappear spontaneously during two to three months observation. Should this not happen, continued ultrasound monitoring and other diagnostic/therapeutic measures are recommended. Rarely, surgical intervention may be required.
Depressed mood and depression are well-known undesirable effects of hormonal contraceptive use (see section 4.8). Depression can be serious and is a well-known risk factor for suicidal behaviour and suicide. Women should be advised to contact their physician in case of mood changes and depressive symptoms, including shortly after initiating the treatment.
Breast cancer:
Risk in pre-menopausal women
A meta-analysis from 54 epidemiological studies reported that there is a slightly increased relative risk (RR = 1.24) of having breast cancer diagnosed in women who are currently using combined oral contraceptives (COCs), mainly using oestrogen-progestogen preparations. The excess risk gradually disappears during the course of the 10 years after cessation of COC use. Because breast cancer is rare in women under 40 years of age, the excess number of breast cancer diagnoses in current and recent COC users is small in relation to the overall risk of breast cancer. The risk of having breast cancer diagnosed in users of progestogen-only methods (POPs, implants and injectables), including Levosert, is possibly of similar magnitude to that associated with COC. A number of observational studies have investigated the risk of being diagnosed with breast cancer in levonorgestrel IUS users, mostly in comparison with the risk in individuals who did not use hormonal contraceptives or in those who did not use LNG-IUS. While some of these studies have suggested a slightly increased relative risk in levonorgestrel IUS users, others have not, and the available evidence is overall less conclusive than for COCs.
General information
Glucose tolerance: Low-dose levonorgestrel may affect glucose tolerance and blood glucose concentrations should be monitored in diabetic users of Levosert.
The T-frame of Levosert contains barium sulphate so that it can be seen on X-rays.
The metabolism of progestagens may be increased by concomitant use of substances known to induce drug-metabolizing enzymes, specifically cytochrome P450 enzymes, such as anticonvulsants (e.g., phenobarbital, phenytoin, carbamazepine) and anti-infectives (e.g. griseofulvin, fluconazole, rifampicin, rifabutin, nevirapine, efavirenz). On the other hand, substances known to inhibit drug-metabolizing enzymes (e.g. itraconazole, ketoconazole) may increase serum concentrations of levonorgestrel. The influence of these drugs on the contraceptive efficacy of Levosert is not known, but it is not believed to be of major importance due to the local mechanism of action.
Pregnancy
Levosert is contraindicated during an existing or suspected pregnancy (see section 4.3). In case of an accidental pregnancy with Levosert in situ (see section 5.1), ectopic pregnancy should be excluded (see section 4.4) and the system should be removed as soon as possible, as there is a high risk for pregnancy complications (abortion, preterm labour, infection and sepsis). Removal of Levosert or probing of the uterus may also result in spontaneous abortion. Should these procedures not be possible or if the woman wishes to continue the pregnancy, the woman should be informed about these risks, and accordingly, such pregnancies should be closely monitored. The woman should be instructed to report all symptoms that suggest complications of the pregnancy, like cramping abdominal pain with fever.
Local exposure to levonorgestrel:
In addition, an increased risk of virilising effects in a female foetus because of the intrauterine exposure to levonorgestrel cannot be excluded. There have been isolated cases of masculinisation of the external genitalia of the female foetus following local exposure to levonorgestrel during pregnancy with an LNG-IUS in place.
Breastfeeding
Levonorgestrel is excreted in very small quantities in breast milk after use in levonorgestrel IUS. Since no risk for the child is expected, breast feeding can be continued during use of Levosert. Uterine bleeding has rarely been reported in women using a levonorgestrel IUS during lactation.
Fertility
The use of levonorgestrel IUS does not alter the course of female fertility after removal of the IUS.
Levosert has no known influence on the ability to drive or use machines.
Undesirable effects are more common during the first months after the insertion, and subside during prolonged use.
Very common undesirable effects (occurring in more than 10% of users) include uterine/vaginal bleeding including spotting, oligomenorrhoea, amenorrhoea (see section 5.1) and benign ovarian cysts.
The frequency of benign ovarian cysts depends on the diagnostic method used, and in clinical trials enlarged follicles have been diagnosed in 12% of the subjects using a levonorgestrel IUS. Most of the follicles are asymptomatic and disappear within three months.
The table below reports adverse reactions by MedDRA system organ class (MedDRA SOCs). The frequencies are based on clinical trial data.
System organ class
Undesirable effects
Very common:
≥ 1/10
Common:
≥ 1/100 to < 1/10
Uncommon:
≥ 1/1,000 to < 1/100
Rare:
≥ 1/10,000 to < 1/1,000
Infections and infestations
Vaginal bacterial infections, Vulvovaginal mycotic infections
Immune system disorders
Hypersensitivity including rash, urticaria and angioedema
Psychiatric disorders
Depressive mood
Nervousness
Decreased libido
Nervous system disorders
Headache
Migraine
Presyncope
Syncope
Vascular disorders
Dizziness
Gastrointestinal disorders
Abdominal pain/discomfort
Nausea
Abdominal distension
Vomiting
Skin and subcutaneous tissue disorders
Acne
Alopecia
Hirsutism
Pruritus
Eczema
Chloasma/skin hyperpigmentation
Rash
Urticaria
Musculoskeletal and connective tissue disorders
Back pain
Pregnancy, puerperium and perinatal conditions
Ectopic pregnancy
Reproductive system and breast disorders
Uterine/vaginal bleeding including spotting, oligomenorrhea, amenorrhea
Benign ovarian cysts
Pelvic pain
Dysmenorrhoea
Vaginal discharge
Vulvovaginitis
Breast tenderness
Breast pain
Dyspareunia
Uterine spasm
Uterine perforation*
Pelvic inflammatory disease
Endometritis
Cervicitis
Papanicolaou smear normal, class II
General disorders and administration site conditions
Procedural pain
Procedural bleeding
Intrauterine contraceptive device expelled
Oedema
Investigations
Weight increased
*This frequency is based on a large prospective comparative non-interventional cohort study in IUS/IUD users, which showed that breast feeding at the time of insertion and insertion up to 36 weeks after giving birth are independent risk factors for perforation (see section 4.4). In clinical trials with levonorgestrel IUS that excluded breast-feeding women the frequency of perforation was "rare".
Infections and infestations
Cases of sepsis (including group A streptococcal sepsis) have been reported following IUS insertion (see section 4.4)
Pregnancy, puerperium and perinatal conditions
When a woman becomes pregnant with Levosert in situ, the relative risk of ectopic pregnancy is increased (see sections 4.4 and 4.6).
Reproductive system and breast disorders
Cases of breast cancer have been reported in levonorgestrel IUS users (frequency not known, see section 4.4).
The following adverse reactions have been reported in connection with the insertion or removal procedure of Levosert: pain, bleeding, and insertion-related vasovagal reaction with dizziness or syncope (see section 4.4). The procedure may also precipitate a seizure in patients with epilepsy.
Reporting of suspected adverse reactions
Reporting suspected adverse reactions after authorisation of the medicinal product is important. It allows continued monitoring of the benefit/risk balance of the medicinal product. Healthcare professionals are asked to report any suspected adverse reactions via the MHRA Yellow Card Scheme (www.mhra.gov.uk/yellowcard) or search for MHRA Yellow Card in the Google Play or Apple App Store.
Not applicable.
Ask anything about Levosert 20 microgram/24 hours Intrauterine Delivery System. The assistant answers only from this leaflet — if the leaflet does not cover it, it will say so. It does not give medical advice.
Answers come from the patient leaflet published on the electronic medicines compendium (emc). They are not medical advice. Ask a pharmacist or your GP if you are unsure. For urgent help call NHS 111, or 999 in an emergency.
We use essential cookies to make the site work. We would also like to set optional cookies to understand how the site is used, so we can improve it. We will not set optional cookies unless you accept. See our cookie policy and privacy policy.