Patient leaflets and SmPCs, drug interaction checker, official dosages and NHS pharmacy opening hours — all in one place.
Patient leaflets and SmPCs, drug interaction checker, official dosages and NHS pharmacy opening hours — all in one place.
The electronic medicines compendium (emc) no longer publishes a Summary of Product Characteristics for this product, which usually means it is no longer marketed in the UK. The patient leaflet below is kept for reference, but the product may not be available.
If you were prescribed this medicine, other products containing Magnesium chloride hexahydrate, Potassium chloride, Sodium acetate trihydrate, Sodium chloride, Sodium gluconate may still be available. Do not stop your treatment — ask your pharmacist or GP what to use instead.
for 2. What you need to know before you use Plasma-Lyte 148 (pH 7.4) Infusion 3. How to use Plasma-Lyte 148 (pH 7.4) Infusion 4. Possible side effects 5. How to store Plasma-Lyte 148 (pH 7.4) Infusion 6. Contents of the pack and other information
Plasma-Lyte 148 (pH 7.4) infusion can be used:
e Plasma-Lyte 148 (pH 7.4) Infusion
1. What Plasma-Lyte 148 (pH 7.4) Infusion is and what it is used for
You must NOT receive Plasma-Lyte 148 (pH 7.4) Infusion if you are suffering from any of the following conditions
Pharmacotherapeutic group: "Electrolytes" – ATC code: "B05BB01" Plasma-Lyte 148 (pH 7.4) Infusion is a solution of the following substances in water:
• • • • •
Sodium, potassium, magnesium, chloride, acetate and gluconate are chemical substances found in the blood.
higher levels of potassium in the blood than normal (hyperkalaemia) kidney failure heart block (a very slow heart beat) disorders in which the blood becomes too alkaline (metabolic or respiratory alkalosis) a deficiency of acid secretion in the stomach (hypochlorhydria) TH-30-02-191
1
•
hypersensitivity to the active substances or to any of the ingredients listed in section 6
•
Warnings and precautions
•
Talk to your doctor or nurse before receiving PlasmaLyte 148 (pH 7.4) infusion if you have or have had any of the following medical conditions:
•
• •
higher levels of sodium in the blood than normal (hypernatraemia) lower levels of calcium in the blood than normal (hypocalcaemia) any condition that means you are more likely to have high blood levels of potassium (hyperkalaemia), such as:
When you are given this infusion, your doctor will take blood and urine samples to monitor:
Other medicines and Plasma-Lyte 148 (pH 7.4) Infusion Tell your doctor or pharmacist if you are taking or have recently taken any other medicines. The use of the following medicines is not recommended while you are receiving an infusion of Plasma-Lyte 148 (pH 7.4) Infusion: TH-30-02-191 2
•
• • • •
potassium-sparing diuretics (certain water tablets, e.g. amiloride, spironolactone, triamterene, potassium canrenoate) angiotensin converting enzyme (ACE) inhibitors (used to treat high blood pressure) angiotensin II receptor antagonists (used to treat high blood pressure) tacrolimus (used to prevent rejection of a transplant and to treat some skin diseases) cyclosporin (used to prevent rejection of a transplant)
•
Plasma-Lyte 148 (pH 7.4) Infusion with food and drink You should ask your doctor about what you can eat or drink.
These medicines can increase the concentration of potassium in your blood. This can be life-threatening. A rise in your blood potassium levels is more likely to occur if you have kidney disease.
Pregnancy, breast-feeding and fertility If you are pregnant or breast-feeding, think you may be pregnant or are planning to have a baby, ask your doctor for advice before taking this medicine.
Some medicines act on the hormone vasopressin. These may include:
You may receive Plasma-Lyte 148 (pH 7.4) Infusion if you are pregnant or breast-feeding. Your doctor will monitor the levels of chemicals in your blood and the amount of fluid in your body. However, if another medicine is to be added to your solution for infusion during pregnancy or breastfeeding you should:
Driving and using machines Ask your doctor or pharmacist for advice before driving or using machines.
Plasma-Lyte 148 (pH 7.4) Infusion You will be given Plasma-Lyte 148 (pH 7.4) Infusion by a doctor or nurse. Your doctor will decide how much you need and when it is to be administered. This will depend on your age, weight, condition and the reason for treatment. The amount you are given may also be affected by other treatments you are receiving.
Other medicines that can affect or be affected by Plasma-Lyte 148 (pH 7.4) Infusion:
You should NOT be given Plasma-Lyte 148 (pH 7.4) Infusion if there are particles floating in the solution or if the pack is damaged in any way. Plasma-Lyte 148 (pH 7.4) Infusion will usually be given to you through a plastic tube attached to a needle in a vein. Usually a vein in your arm is used to give you the infusion. However, your doctor may use another method to give you the medicine.
TH-30-02-191 3
• •
Before and during the infusion, your doctor will monitor:
twitching of the muscles contractions of muscles
If you develop any of these symptoms, you must inform your doctor immediately. Your infusion will be stopped and you will be given treatment depending on the symptoms. If a medicine has been added to your Plasma-Lyte 148 (pH 7.4) Infusion before over-infusion occurs, that medicine may also cause symptoms. You should read the Package Leaflet of the added medicine for a list of possible symptoms.
Any unused solution should be thrown away. You should NOT be given an infusion of Plasma-Lyte 148 (pH 7.4) Infusion from a bag that has been partly used.
Stopping your Plasma-Lyte 148 (pH 7.4) Infusion
If you receive more Plasma-Lyte 148 (pH 7.4) Infusion than you should
Your doctor will decide when to stop giving you this infusion.
If you are given too much Plasma-Lyte 148 (pH 7.4) Infusion (over-infusion) or it is given too fast, this may lead to the following symptoms:
If you have any further questions on the use of this medicine, ask your doctor or nurse.
Like all medicines, this medicine can cause side effects, although not everybody gets them. If you have any of the following symptoms you should tell your doctor or nurse immediately. These may be signs of a very severe or even fatal allergic (hypersensitivity) reaction:
–
• • • • • • • • • • • • • • • • • •
escape of the infusion solution into the tissues around the vein (extravasation). This can damage the tissues and cause scarring. an excess of fluid in the body (hypervolaemia). fits (seizures) hives (urticaria) serious allergic reaction which causes difficulty in breathing or dizzines (anaphylactoid reaction) a fast heartbeat (tachycardia) palpitations chest pain chest discomfort shortness of breath (dyspnea) respiratory rate increased flushing hyperaemia feeling of weakness (asthenia) feeling abnormal piloerection oedema peripheral fever (pyrexia) low levels of sodium in the blood that may be acquired during hospitalization (nosocomial hyponatraemia) and related neurological disorders (acute hyponatraemic encephalopathy). Hyponatraemia can lead to irreversible brain injury and death due to cerebral oedema/swelling (see also section 2 "Warnings and precautions").
Ireland: HPRA Pharmacovigilance, Earlsfort Terrace, IRL – Dublin 2; Tel: +353 1 6764971; Fax: +353 1 6762517. Website: www.hpra.ie; E-mail: [email protected]. Malta Website: www.medicinesauthority.gov.mt/adrportal
Plasma-Lyte 148 (pH 7.4) Infusion Keep this medicine out of the sight and reach of children. This medicinal product does not require any special temperature storage conditions. Do not use this medicine after the expiry date which is stated on the bag. The expiry date refers to the last day of that month. Do not use this medicine if you notice particles floating in the solution or if the unit is damaged in any way.
If a medicine has been added to the solution for infusion, the added medicine may also cause side effects. These side effects will depend on the medicine that has been added. You should read the Package Leaflet of the added medicine for a list of possible symptoms.
What Plasma-Lyte 148 (pH 7.4) Infusion contains The active substances are:
Other side effects noted with similar products
Reporting of side effects If you get any side effects, talk to your doctor or nurse. This includes any possible side effects not listed in this leaflet. You can also report side effects directly via the national reporting system listed below. By reporting side effects you can help provide more information on the safety of this medicine.
What Plasma-Lyte 148 (pH 7.4) Solution for Infusion looks like and contents of the pack Plasma-Lyte 148 (pH 7.4) Solution for Infusion is a clear solution, free from visible particles. It is supplied in polyolefin/polyamide plastic bags (Viaflo). Each bag is wrapped in a sealed, protective, outer plastic overpouch.
United Kingdom: Via the Yellow Card Scheme at: www.mhra.gov.uk/yellowcard
TH-30-02-191 5
The bag sizes are:
This medicine is authorised in the Member States of the uropean Economic Area, and in the United Kingdom (Northern Ireland),under the following names:
The bags are supplied in cartons. Each carton contains one of the following quantities:
Austria: Belgium, Luxemburg:
Plasmalyt-Infusionslösung
Plasmalyte A Viaflo, solution pour perfusion Croatia: Plasma-Lyte 148 (pH 7,4) Viaflo, otopina za infuziju Czech Republic: Plasmalyte roztok Cyprus: Plasma-Lyte 148 (pH 7,4) Solution for infusion Spain: Viaflo Plasmalyte 148 (pH 7,4), solución para perfusion Denmark: Plasmalyte, infusionsvæske, opløsning Finland: Plasmalyte infuusioneste, liuos France: Plasmalyte Viaflo, solution pour perfusion Greece: Plasma-Lyte 148 (pH 7,4) Solution for infusion Iceland: Plasmalyte innrennslislyf, lausn Ireland: Plasma-Lyte 148 (pH 7.4) Solution for infusion Italy: CrystalSol Solution for infusion Lithuania: Plasmalyte infuzinis tirpalas Malta: Plasma-Lyte 148 (pH 7.4) Solution for infusion Netherlands: Plasma-Lyte 148, oplossing voor infusie Norway: Plasmalyte infusjonsvæske, oppløsning Poland: Plasmalyte roztwór do infuzji Portugal: Plasma-Lyte (ph 7,4) 148 Viaflo Slovenia: Plaslyte raztopina za infundiranje Slovakia: Plasmalyte infúzny roztok Sweden: Plasmalyte infusionsvätska, lösning United Kingdom: Plasma-Lyte 148(pH 7.4) Solution for Infusion
Not all pack sizes may be marketed.
Marketing Authorisation Holder and Manufacturers Marketing Authorisation Holder: United Kingdom Baxter Healthcare Ltd. Caxton Way, Thetford, Norfolk, IP24 3SE, United Kingdom Ireland and Malta Baxter Holding B.V. Kobaltweg 49, 3542CE Utrecht, Netherlands Manufacturers for Great Britain: Baxter Healthcare Ltd. Caxton Way Thetford Norfolk IP24 3SE United Kingdom Baxter S.A. Boulevard René Branquart, 80 7860 Lessines Belgium Bieffe Medital S.A. Ctra de Biescas-Senegüé 22666 Sabiñánigo (Huesca) Spain Manufacturers for Ireland and Malta:
This leaflet was last revised in July 2023 For information about Plasma-Lyte 148 (pH 7.4) Infusion or to request this leaflet in formats such as audio or large print please contact the Marketing Authorisation Holder: Tel: +44 (0) 1635 206345.
Baxter S.A. Boulevard René Branquart, 80 7860 Lessines Belgium Bieffe Medital S.A. Ctra de Biescas-Senegüé 22666 Sabiñánigo (Huesca) Spain
Baxter, Plasma-Lyte and Viaflo are trademarks of Baxter International lnc.
TH-30-02-191 6
Plasma-Lyte 148 (pH 7.4) Solution for Infusion The following information is intended for healthcare professionals only:
c.
Check the solution for clarity and absence of foreign matters. If solution is not clear or contains foreign matters, discard the solution.
Handling and Preparation
2. Preparation for administration
This solution should be inspected visually for particulate matter and discolouration prior to administration whenever solution and container permit. Do not administer unless the solution is clear and the seal is intact.Do not remove unit from overwrap until ready for use. The inner bag maintains the sterility of the product. Administer immediately following the insertion of infusion set. Do not use plastic containers in series connections. Such use could result in air embolism due to residual air being drawn from the primary container before the administration of the fluid from the secondary container is completed. Pressurizing intravenous solutions contained in flexible plastic containers to increase flow rates can result in air embolism if the residual air in the container is not fully evacuated prior to administration. Use of a vented intravenous administration set with the vent in the open position could result in air embolism. Vented intravenous administration sets with the vent in the open position should not be used with flexible plastic containers. The solution is for intravenous administration through sterile administration set using aseptic technique. The equipment should be primed with the solution in order to prevent air entering the system. Additives may be introduced before infusion or during infusion through the re-sealable medication port. Adding other medications or using an incorrect administration technique might cause the appearance of fever reactions due to the possible introduction of pyrogens. In case of an adverse reaction, infusion must be stopped immediately. Discard after single use. Discard any unused portion. Do not reconnect partially used bags.
Use sterile material for preparation and administration. a. Suspend container from eyelet support. b. Remove plastic protector from outlet port at bottom of container:
3. Techniques for injection of additive medications Warning: Additives may be incompatible Check additive compatibility with both the solution and container prior to use.When additive is used, verify isotonicity prior to parenteral administration. Thorough and careful aseptic mixing of any additive is mandatory. Solutions containing additives should be used immediately and not stored. (see Paragraph 5 "Incompatibilities of additive medications" below). To add medication before administration a. Disinfect medication port. b. Using syringe with 19 gauge (1.10 mm) to 22 gauge (0.70 mm) needle, puncture resealable medication port and inject. c. Mix solution and medication thoroughly. For high-density medication such as potassium chloride, tap the ports gently while ports are upright and mix. Caution: Do not store bags containing added medications.
1. Opening a. Remove the Viaflo container from the overpouch just before use. b. Check for minute leaks by squeezing inner bag firmly. If leaks are found, discard solution, as sterility may be broken.
To add medication during administration a. Close clamp on the set. TH-30-02-191 7
5. Incompatibilities of additive medications
b. Disinfect medication port. c. Using syringe with 19 gauge (1.10 mm) to 22 gauge (0.70 mm) needle, puncture resealable medication port and inject. d. Remove container from IV pole and/or turn to an upright position. e. Evacuate both ports by tapping gently while the container is in an upright position. f. Mix solution and medication thoroughly. g. Return container to in use position, re-open the clamp and continue administration.
When introducing additives to Plasma-Lyte 148 (pH 7.4), aseptic technique must be used. Mix the solution thoroughly when additives have been introduced. Do not store solutions containing additives. Incompatibility of the medicinal product to be added with the solution in Viaflo container must be assessed before addition. The Instructions for Use of the medicinal product to be added must be consulted.
4. Shelf life after first opening: The product should be used immediately after opening. In-use shelf-life after reconstitution with additives:
Before adding a substance or medication, verify it is soluble and/or stable in water and that the pH range of Plasma-Lyte 148 (pH 7.4) is appropriate (pH 6.5 – 8.0). After addition, check for a possible colour change and/or the appearance of precipitates, insoluble complexes or crystals.
Chemical and physical stability of any additive at the pH of Plasmalyte 148 (pH 7.4) solution in the Viaflo container should be established prior to use. From a microbiological point of view, the diluted product should be used immediately. If not used immediately, in-use storage times and conditions prior to use are the responsibility of the user and would normally not be longer than 24 hours at 2 to 8°C unless reconstitution has taken place in controlled and validated aseptic conditions.
Those additives known to be incompatible should not be used.
Baxter, Plasma-Lyte and Viaflo are trademarks of Baxter International lnc.
TH-30-02-191 8
Plasma-Lyte 148 (pH 7.4) solution for infusion comes as infusion. Always follow the dose your doctor or pharmacist has given you, and read the leaflet that comes with the medicine.
The active substance in Plasma-Lyte 148 (pH 7.4) solution for infusion is magnesium chloride hexahydrate, potassium chloride, sodium acetate trihydrate, sodium chloride, sodium gluconate.
This leaflet reproduces the patient information leaflet approved for Plasma-Lyte 148 (pH 7.4) solution for infusion, as published on the electronic medicines compendium (emc). The version printed inside your medicine’s packaging is the one that applies to you.
Whether a medicine is available over the counter or on prescription only depends on its licence. Check the leaflet, or ask your pharmacist — they can tell you straight away.
The text above reproduces the patient information leaflet approved for this medicine, restructured for easier reading.
Plasma-Lyte 148 (pH 7.4) is indicated:
- for fluid replacement (e.g. after burns, head injury, fracture, infection, and peritoneal irritation),
- as intraoperative fluid replacement,
- in haemorrhagic shock and clinical conditions requiring rapid blood transfusions (compatibility with blood),
- in mild to moderate metabolic acidosis, also in case of lactate metabolism impairment.
Posology:
Adults, older patients and adolescents (age 12 years and over):
Fluid balance, serum electrolytes and acid-base balance should be monitored before and during administration, with particular attention to serum sodium in patients with increased non-osmotic vasopressin release (syndrome of inappropriate antidiuretic hormone secretion, SIADH) and in patients co-medicated with vasopressin agonist drugs, due to the risk of hospital acquired hyponatraemia (see sections 4.4, 4.5 and 4.8). Monitoring of serum sodium is particularly important for hypotonic fluids.
Plasma-Lyte 148 (pH 7.4) solution has a tonicity of 295 mOsm/l (approx.)
The infusion rate and volume depend on the age, weight, clinical condition (e.g. burns, surgery, head-injury, infections), and concomitant therapy should be determined by the consulting physician experienced in intravenous fluid therapy (see sections 4.4. and 4.8).
The recommended dosage is: 500 ml to 3 litres / 24 h
Administration rate:
The infusion rate is usually 40 mL/kg/24h in adults, the elderly and adolescents.
When used for intraoperative fluid replacement, normal rate can be higher and is about 15 mL/kg/h.
Use in Geriatric Patients
When selecting the type of infusion solution and the volume/rate of infusion for a geriatric patient, consider that geriatric patients are generally more likely to have cardiac, renal, hepatic, and other diseases or concomitant drug therapy.
Paediatric population
Safety and effectiveness of Plasma-Lyte 148 (pH 7.4) in children have not been established by adequate and well controlled trials. Treatment of paediatric patients is described in literature.
The dosage varies with weight:
•
0-10 kg body weight:
up to 100 ml/kg/24h
•
10-20 kg body weight:
1000 ml + (50 ml/kg over 10 kg)/24h
•
> 20 kg body weight:
1500 ml + (20 ml/kg over 20 kg)/24h.
The administration rate varies with weight:
•
0-10 kg body weight:
6-8 ml/kg/h
•
10-20 kg body weight:
4-6 ml/kg/h
•
> 20 kg body weight:
2-4 ml/kg/h
Method of administration:
The administration is performed by intravenous route.
The solution should be administered with sterile equipment using an aseptic technique. The equipment should be primed with the solution in order to prevent air entering the system.
This solution can be administered before, during or after a blood transfusion.
Due to its iso-osmolality, this solution can be administered through a peripheral vein.
The solution should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. Do not administer unless the solution is clear and the seal is intact.
Do not remove unit from overwrap until ready for use. The inner bag maintains the sterility of the solution. Administer immediately following the insertion of infusion set.
Do not use plastic containers in series connections. Such use could result in air embolism due to residual air being drawn from the primary container before the administration of the fluid from the secondary container is completed. Pressurizing intravenous solutions contained in flexible plastics containers to increase flow rates can result in air embolism if the residual air in the container is not fully evacuated prior to administration.
Use of a vented intravenous administration set with the vent in the open position could result in air embolism. Vented intravenous administration sets with the vent in the open position should not be used with flexible plastic containers.
Additives may be introduced before infusion or during infusion through the injection site
The solution is contra-indicated in patients presenting:
- Hyperkalaemia
- Renal failure
- Heart block
- Metabolic or respiratory alkalosis
- Hypochlorhydria
- Hypersensitivity to the active substances or to any of the excipients listed in section 6.1
WARNINGS
Electrolyte balance
Plasma-Lyte 148 (pH 7.4) is not indicated for the treatment of hypochloraemic hypokalaemic alkalosis.
Plasma-Lyte 148 (pH 7.4) is not indicated for the primary treatment of severe metabolic acidosis neither for the treatment of hypomagnesaemia.
Use in Patients with or at Risk for and from Hypermagnaesemia
Parenteral magnesium salts should be used with caution in less severe degrees of renal impairment and in patients with myasthenia gravis. Patients should be monitored for clinical signs of excess magnesium, particularly when being treated for eclampsia. (See also section 4.5 – Interactions with other Medicinal Products and other forms of interaction)
Use in patients with Hypocalcaemia
Plasma-Lyte 148 (pH 7.4) contains no calcium, and an increase in plasma pH due to its alkalinizing effect may lower the concentration of ionized (not protein-bound) calcium. Plasma-Lyte 148 (pH 7.4) should be administered with particular caution to patients with hypocalcaemia.
Use in Patients with or at Risk for Hyperkalaemia
Solutions containing potassium salts should be administered with caution to patients with cardiac disease or conditions predisposing to hyperkalaemia such as renal or adrenocortical insufficiency, acute dehydration, or extensive tissue destruction as occurs with severe burns. The plasma potassium level of the patient should be particularly closely monitored in patients at risk of hyperkalaemia.
The following combinations are not recommended; they increase the concentration of potassium in the plasma and may lead to potentially fatal hyperkalaemia notably in case of renal failure increasing the hyperkalaemic effects (see 4.5).
- Concomitant use with potassium-sparing diuretics (amiloride, potassium canreonate, spironolactone, triamterene)
- Angiotensin converting enzyme inhibitors (ACEi) and, by extrapolation, angiotensin II receptor antagonists : hyperkalaemia potentially lethal
- Tacrolimus, cyclosporin
Use in patients with potassium deficiency
Although Plasma-Lyte 148 (pH 7.4) solution has a potassium concentration similar to the concentration in plasma, it is insufficient to produce a useful effect in case of severe potassium deficiency and therefore it should not be used for this purpose.
Fluid balance/renal function.
Risk of Fluid and/or Solute Overload and Electrolyte Disturbances
The patient's clinical status and laboratory parameters (fluid balance, blood and urine electrolytes as well as acid-base balance) must be monitored during use of this solution.
Depending on the volume and rate of infusion, intravenous administration of Plasma-Lyte 148 (pH 7.4) can cause − fluid and/or solute overload resulting in overhydration/hypervolaemia therefore high volume infusion must be used under specific monitoring in patients with cardiac, pulmonary or renal failure.
High volume infusion must be used under specific monitoring in patients with cardiac or pulmonary failure and in patients with non-osmotic vasopressin release (including SIADH), due to the risk of hospital-acquired hyponatraemia (see below).
Hyponatraemia
Patients with non-osmotic vasopressin release (e.g. in acute illness, pain, post-operative stress, infections, burns, and CNS diseases), patients with heart-, liver- and kidney diseases and patients exposed to vasopressin agonists (see section 4.5) are at particular risk of acute hyponatraemia upon infusion of hypotonic fluids.
Acute hyponatraemia can lead to acute hyponatraemic encephalopathy (cerebral oedema) characterized by headache, nausea, seizures, lethargy and vomiting. Patients with cerebral oedema are at particular risk of severe, irreversible and life-threatening brain injury.
Children, women in the fertile age and patients with reduced cerebral compliance (e.g. meningitis, intracranial bleeding, cerebral contusion and brain oedema) are at particular risk of the severe and life-threatening brain swelling caused by acute hyponatraemia.
Use in Patients with Hypervolaemia or Overhydration, or Conditions that Cause Sodium Retention and Oedema
Plasma-Lyte 148 (pH 7.4) should be administered with particular caution to hypervolaemic or overhydrated patients.
Solutions containing sodium chloride should be carefully administered to patients with hypertension, heart failure, peripheral or pulmonary edema, impaired renal function, pre-eclampsia, aldosteronism, or other conditions associated with sodium retention (see also Section 4.5 – Interactions with other Medicinal Products and forms of interaction).
Use in Patients with Severe Renal Impairment
Plasma-Lyte 148 (pH 7.4) should be administered with particular caution to patients with severe renal impairment. In such patients administration of Plasma-Lyte 148 (pH 7.4) may result in sodium and/or potassium or magnesium retention.
Acid-base balance
Use in Patients with or at Risk for Alkalosis
Plasma-Lyte 148 (pH 7.4) should be administered with particular caution to patients with alkalosis or at risk for alkalosis. Excess administration of Plasma-Lyte 148 (pH 7.4) can result in metabolic alkalosis because of the presence of acetate and gluconate ions.
Other warnings
Hypersensitivity Reactions
Hypersensitivity/infusion reactions, including anaphylactoid reactions, have been reported with Plasma-Lyte 148 (pH 7.4).
The infusion must be stopped immediately if any signs or symptoms of a suspected hypersensitivity reaction develop. Appropriate therapeutic countermeasures must be instituted as clinically indicated.
Administration
Administration in the postoperative period shortly after recovery from neuromuscular block should be used with caution since magnesium salts can lead to recurarisation effect.
When used concomitantly with parenteral nutrition, electrolyte supply should be taken into account and adjusted accordingly.
PRECAUTIONS
Interference with laboratory tests for gluconate containing solutions
There have been reports of false-positive test results using the Bio-Rad Laboratories Platelia Aspergillus EIA test in patients receiving Baxter gluconate containing Plasmalyte solutions. These patients were subsequently found to be free of Aspergillus infection. Therefore, positive test results for this test in patients receiving Baxter gluconate containing Plasmalyte solutions should be interpreted cautiously and confirmed by other diagnostic methods.
Administration
Adding other medications or using an incorrect administration technique might cause the appearance of fever reactions due to the possible introduction of pyrogens. In case of an adverse reaction, infusion must be stopped immediately.
For information on incompatibilities and preparation of the product and additives, please see section 6.2 and 6.6.
Drugs leading to an increased vasopressin effect
The below listed drugs increase the vasopressin effect, leading to reduced renal electrolyte free water excretion and may increase the risk of hospital acquired hyponatraemia following inappropriately balanced treatment with i.v. fluids (see sections 4.2, 4.4 and 4.8).
• Drugs stimulating vasopressin release include: Chlorpropamide, clofibrate, carbamazepine, vincristine, selective serotonin reuptake inhibitors, 3.4-methylenedioxy-N-methamphetamine, ifosfamide, antipsychotics, narcotics
• Drugs potentiating vasopressin action include: Chlorpropamide, NSAIDs, cyclophosphamide
• Vasopressin analogues include: Desmopressin, oxytocin, terlipressin
Other medicinal products increasing the risk of hyponatraemia also include diuretics in general and antiepileptics such as oxcarbazepine.
Interaction related to the presence of sodium:
- Corticoids/Steroids and carbenoxolone, which are associated with the retention of sodium and water (with oedema and hypertension).
Interaction related to the presence of potassium:
The following combinations increase the concentration of potassium in the plasma and may lead to potentially fatal hyperkalaemia notably in case of renal failure increasing the hyperkalaemic effects:
- Potassium-sparing diuretics (amiloride, potassium canreonate, spironolactone, triamterene, alone or in combination) (see 4.4),
- Angiotensin converting enzyme inhibitors (ACEi) and, by extrapolation, angiotensin II receptor antagonists: hyperkalaemia potentially lethal (see 4.4),
Tacrolimus, cyclosporin (see 4.4)
Administration of potassium in patients treated with such medications can produce severe and potentially fatal hyperkalaemia, particularly in patients with severe renal insufficiency.
Interaction related to the presence of magnesium:
Neuromuscular blockers such as tubocurarine, suxamethonium, and vecuronium whose effects are enhanced by the presence of magnesium.
Acetylcholine whose release and effects are reduced by magnesium salts what may contribute to neuromuscular blockade.
Aminoglycoside antibacterials and nifedipine that have additive effects with parenteral magnesium and enhanced the neuromuscular blocking.
Interaction related to the presence of acetate and gluconate (which are metabolised into bicarbonate):
Caution is advised when administering Plasma-Lyte 148 (pH 7.4) to patients treated with drugs for which renal elimination is pH dependent. Due to its alkalinizing effect (formation of bicarbonate), Plasma-Lyte 148 (pH 7.4) may interfere with the elimination of such drugs.Renal clearance of acidic drugs such as salicylates, barbiturates and lithium may be increased because of the alkalinisation of urine by the bicarbonate resulting from acetate and gluconate metabolism.
Renal clearance of alkaline drugs such as sympathomimetics (e.g. ephedrine, pseudoephedrine) and stimulants (e.g. dexamphetamine sulphate, phenfluramine hydrochloride) may be decreased.
Pregnancy and lactation
There are no adequate data from the use of Plasma-Lyte 148 (pH 7.4) solution for infusion in pregnant or lactating women. The potential risks and benefits for each specific patient should be carefully considered before using Plasma-Lyte 148 (pH 7.4) solution for infusion in pregnancy or lactating woman.
Plasma-Lyte® 148 (pH 7.4) solution should be administrated with special caution for pregnant women during labour particularly as to serum-sodium if administered in combination with oxytocin (see section 4.4, 4.5 and 4.8).
Fertility
There is no information on the effects Plasma-Lyte 148 (pH 7.4) solution for infusion on fertility.
There is no information of the effects of Plasma-Lyte 148 (pH 7.4) solution for infusion on the ability to drive and use machines.
The following adverse reactions have been reported in the post-marketing experience, with various electrolyte solutions similar to Plasma-lyte, listed by MedDRA System Organ Class (SOC), then by Preferred Term in order of severity, where feasible.
Frequency is defined as very common (≥ 1/10); common (≥ 1/100 to < 1/10); uncommon (≥ 1/1000 to < 1/100): rare (≥ 1/10,000 to < 1/1000); very rare (< 1/10,000); and not known (cannot be estimated from the available data)
System Organ Class (SOC)
MedDRA Preferred Term
Frequency
Immune system disorders
Hypersensitivity/infusion reaction (including Anaphylactoid reaction, and the following manifestations:
Tachycardia,
Palpitations,
Chest pain,
Chest discomfort,
Dyspnea,
Respiratory rate increased,
Flushing,
Hyperaemia,
Asthenia,
Feeling abnormal,
Piloerection,
Oedema peripheral,
Pyrexia
Urticaria
*Hypotension,Wheezing, Cold sweat, Chills, Hyperkalaemia)
Not known
Metabolism and nutrition disorders
Hypervolaemia
Hospital acquired hyponatraemia**
Not known
Nervous system disorders
Seizures
Acute hyponatraemic encephalopathy**
Not known
Vascular disorders
Thrombophlebitis
Venous thrombosis
Not known
Not known
Skin and subcutaneous tissue disorders
Urticaria
Not known
General disorders and administration site conditions
Infusion site reactions
(e.g., Burning sensation
Fever
Injection site pain
Injection site reaction
Injection site phlebitis
Injection site irritation
Injection site infection
Extravasation)
Not known
Investigations
False positive laboratory results (Bio-Rad Laboratories' Platelia Aspergillus EIA test) (see Section 4.4)
Not known
* The adverse reactions highlighted in italic are reported for other similar products
**Hospital acquired hyponatraemia may cause irreversible brain injury and death, due to development of acute hyponatraemic encephalopathy, frequency unknown (see sections 4.2. 4.4, 4.5).
Reporting of suspected adverse reactions
Reporting suspected adverse reactions after authorisation of the medicinal product is important. It allows continued monitoring of the benefit/risk balance of the medicinal product. Healthcare professionals are asked to report any suspected adverse reactions via:
Yellow Card Scheme
Website: www.mhra.gov.uk/yellowcard
Overuse or too fast administration may lead to water and sodium overload with a risk of oedema, particularly when there is a defective renal sodium excretion. In this case extra renal dialysis may be necessary.
Excessive administration of potassium may lead to the development of hyperkalaemia, especially in patients with renal impairment. Symptoms include paresthesia of the extremities, muscle weakness, paralysis, cardiac arrhythmias, heart block, cardiac arrest, and mental confusion. Treatment of hyperkalaemia involves the administration of calcium, insulin (with glucose) sodium bicarbonate, exchange resins or dialysis.
Excessive parenteral administration of magnesium salts leads to the developments of hypermagnesaemia, important signs of which are loss of deep tendon reflexes and respiratory depression, both due to neuromuscular blockade. Other symptoms of hypermagnesaemia may include nausea, vomiting, flushing of the skin, thirst, hypotension due to peripheral vasodilatation, drowsiness, confusion, muscle weakness, bradycardia, coma, and cardiac arrest. A patient with supralethal hypermagnesaemia was successfully treated using assisted ventilation, calcium chloride, administered intravenously, and forced diuresis with mannitol infusions.
Excessive administration of chloride salts may cause a loss of bicarbonate with an acidifying effect.
Excessive administration of compounds, such as sodium acetate and sodium gluconate, which are metabolised to form the bicarbonate anion may lead to hypokalaemia and metabolic alkalosis, especially in patients with impaired renal function. Symptoms may include mood changes, tiredness, shortness of breath, muscle weakness, and irregular heartbeat. Muscle hypertonicity, twitching, and tetany may develop especially in hypocalcaemic patients. Treatment of metabolic alkalosis associated with bicarbonate overdose consists mainly of appropriate correction of fluid and electrolyte balance.
When overdose is related to medications added to the solution infused, the signs and symptoms of over infusion will be related to the nature of the additive being used. In the event of accidental over infusion, treatment should be discontinued and the patient should be observed for the appropriate signs and symptoms related to the drug administered. The relevant symptomatic and supportive measures should be provided as necessary.
Medicines sold in Romania with the same active substance: Cunoscut în România ca
⚠ Not the same combination. This medicine contains Magnesium chloride hexahydrate, Potassium chloride, Sodium acetate trihydrate, Sodium chloride, Sodium gluconate. The products below do not contain exactly the same set of active substances — they are not direct substitutes.
Some of these do not contain exactly the same active substances — check each one. The strength, the form and whether you need a prescription can differ. Always ask a pharmacist before you switch. Romanian medicines in the UK →
Medicines sold in Poland with the same active substance: W Polsce znany jako
⚠ Not the same combination. This medicine contains Magnesium chloride hexahydrate, Potassium chloride, Sodium acetate trihydrate, Sodium chloride, Sodium gluconate. The products below do not contain exactly the same set of active substances — they are not direct substitutes.
Some of these do not contain exactly the same active substances — check each one. The strength, the form and whether you need a prescription can differ. Always ask a pharmacist before you switch. Polish medicines in the UK →
Ask anything about Plasma-Lyte 148 (pH 7.4) solution for infusion. The assistant answers only from this leaflet — if the leaflet does not cover it, it will say so. It does not give medical advice.
Answers come from the patient leaflet published on the electronic medicines compendium (emc). They are not medical advice. Ask a pharmacist or your GP if you are unsure. For urgent help call NHS 111, or 999 in an emergency.
We use essential cookies to make the site work. We would also like to set optional cookies to understand how the site is used, so we can improve it. We will not set optional cookies unless you accept. See our cookie policy and privacy policy.